#JANSEN

Jansen Economy 60 RS smoke control door

Jansen Economy smoke protection systems enable efficient production of flush smoke control doors compliant with DIN 18095. The 60 mm deep profiles are distinguished by their narrow face widths. A wide range of styles and functional variations have been tested and approved.

System description

Materials / Surface

  • Uncoated or strip-galvanised steel, suitable for powder coating or stove-enamellingElement Types
  • Single and double doors, with or without side panels and transom windowsEquipment
  • Steel and stainless steel hinges for welding or screw-fit
  • Integrated door closers
  • Multipoint locks (motorised options available)
  • Designer glazing beads
  • Emergency locks and panic push-bars

performance characteristics

Special Technical Features

  • Central glazed panel
  • Dry glazing and glazing with putty
  • Available with combined fire protection and smoke protection, or solely with fire protection (Fire protection doors Jansen Economy 60)
  • Option to exclude smoke protection (Jansen Economy 60 door)

Product details

Test Certificates

  • Smoke control in accordance with DIN 18095
  • Smoke control tested in accordance with EN 1634-3
  • Emergency exit door in accordance with EN 1125 / EN 179
  • Burglar resistance class RC3